- Display: 12.1" real color TFT screen
- Power Requirements: AC: 100 ~ 240V, 50Hz/60Hz, DC: Built-in rechargeable 11.1V 24wh Li-ion battery 2h operating after full charge 5min operating after low battery alarm
- Dimension and Weight: Equipment: 340×245×134mm; 2.798kg (about) Package: 380×350×300mm; 4.598 kg(about)
- Date Storage: Trend diagram/table: 7x24h, NIBP review: 400 events, Wave review: 100min, Alarm review: 100 alarm events, Support drug concentration titration analysis
- ECG: 5 Leads: RA, LA, LL, RL, V, Lead mode: I, II, III, AVR, AVL, AVF, V, Gain: x 1.25mm/mV, 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV (error ≤ 5%), Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s (error ≤ ± 10%), Bandwidth: Surgery 1 ~ 25 Hz, Monitor 0.5 ~ 40Hz, Diagnostic 0.05 ~ 130 Hz, Sensitivity: >200 µ V P-P, CMRR: ≥ 112dB, Differential Input Impedance: >5M, ohm Electrode Offset Potential: ±300mV, Polarization Voltage: ≥± 500mV, Input Impedance: ≥ 5 M, Calibration Voltage: 1mV ± 5%
- NIBP: Method: Oscillometer, Measure mode: Manual, Auto, STAT, Measure interval in auto mode: 1~5/10/15/30/60/90/120/180/240/480min, Measure period in STAT mode: 5min, Pulse rate range: 40~ 240bpm
- Measure & alarm range:
|
Adult SYS 40~280mmHg DIA 10~220mmHg MEAN 20~240mmHg |
Pediatric SYS 40~220mmHg DIA 10~160mmHg MEAN 20~170mmHg |
Neonate SYS 40~135mmHg DIA 10~100mmHg MEAN 20~110mmHg |
Static Pressure Measurement Range: 0~ 300mmHg, Accuracy: ± 3mmHg, Resolution: 1mmHg Accuracy, Max. Mean Error: ± 5mmHg, Max. Standard Deviation: 8mmHg Overpressure protection: Adult 300mmHg, Pediatric 240mmHg, Neonatal 150mmHg
- SpO2: Range: 0 ~ 100%, Resolution: 1%, Accuracy: 70%~100% ± 2% & 40%~69% ± 3%
- Pulse Rate: Measure/alarm range: 20 ~ 300bpm, Resolution: 1bpm, Accuracy: ± 3bpm
- TEMP: Channel: 2, Measure & alarm range: 0° ~ 50° C, Resolution: 0.1°C, Accuracy (no sensor): ±0.1° C (0°~50° C)
- Standard accessories: NIBP cuff & tube, ECG cable & electrodes, SpO2 sensor, TEMP probe, Lithium-ion battery, Power cable, Operator's manual
Shipping & Delivery
Shipping & Delivery
Fast & Safe Delivery Across India
Orders are dispatched within 2–5 working days, depending on availability and location.
Secure Packaging
Each unit is shipped with multi-layer protective packaging to prevent transit damage.
Order Tracking Available
A tracking ID will be shared once the product is dispatched.
Quality Checked Before Dispatch
Every machine is tested before shipping to ensure proper functioning.
Return & Refund Policy
Return & Refund Policy
7-Day Return Policy
Returns are accepted within 7 days only if the product is damaged, defective, or incorrect.
Full Refund or Replacement
After verification, customers may choose a full refund or product replacement.
Proof Required
Clear photos or videos of the damage/defect must be submitted for approval.
Non-Returnable Conditions
Items cannot be returned if they are used, tampered with, or physically damaged by the customer.
Share
100% Genuine Products
Fast & Safe Delivery
Expert Customer Assistance