  • Display: 14 inch, TFT LCD screen, Resolution: 1366*768
  • Application Range: Adult/Pediatric/Neonatal/Medicine/Surgery/Operating Room/ICU/CCU
  • Electrical Specifications: Power supply voltage: AC 100~240V AC, power frequency: 50/60Hz, maximum input power 70VA, Fuse F2AL 250V, working method: continuous, Built-in lithium battery: d.c11.1V not less than 2000mA, working time ≥ 2 hours.
  • ECG: Gain: X0.25, X0.5, X1, X2, Auto, Waveform speed: 12.5mm/s, 25mm/s, 50mm/s, Sensitivity>200uV (peak-to-peak) Bandwidth: Diagnostic mode: 0.05~130Hz, Monitoring mode: 0.5~40Hz, Operation mode: 1~20Hz, Common Mode Rejection Ratio: Diagnostic mode: >90dB, Monitoring mode: >100dB, Operation mode: >100dB, Electrode polarization voltage: ±300mV Input impedance≥5M, DC bias voltage: ±300mV, Calibration signal: 1mV (peak-to-peak), accuracy ±5%, ST segment detection measurement- Measurement range: -2.0mV~+2.0mV, Measurement accuracy: within the range of -0.8mV~+0.8mV, with measurement error ±0.02mV or ±10%, whichever is greater, other ranges are undefined
  • ST Segment: Range -2.0 to +2.0 mV, Adjustment 0.1 mV
  • NIBP: Measuring Range and Precision Range- Adult Systolic blood pressure 40~270mmHg, Diastolic blood pressure 10~215mmHg, Mean blood pressure 20~235mmHg, Static pressure range 0~300mmHg, Static pressure precision ±3mmHg, Pressure precision- Max. average error: ±5mmHg; Max. standard deviation: 8mmHg
  • SPO2: Range 0~100%, Resolution 1%, Accuracy 70% to 100% with measurement error ±2%
  • Pulse Rate: Range 30~300bpm, Resolution 1bpm, Accuracy ±3bpm. Update time 1s
  • Heart Rate: Adult 15-300bpm, Neonatal/Child 15-350bpm, Accuracy ±1% or ±1bpm
  • Respiration Rate: Adult 0~120BrPM, Children and neonates 0 to 150 BrPM, In the range of 7BrPM~120BrPM, the measurement error should be ±2BrPM. Errors in other ranges are undefined.
  • Temperature: Range 0~50C, Resolution 0.1C, Accuracy ± 0.1C (excluding sensor error)
  • Accessories: Standard: NIBP cuff & tube, ECG cable & electrodes, SpO 2 sensor, TEMP probe, Lithium-ion battery, Power cable, Operator’s manual. Optional: End-tidal CO, Recorder, Dual IBP

Shipping & Delivery

Fast & Safe Delivery Across India
Orders are dispatched within 2–5 working days, depending on availability and location.

Secure Packaging
Each unit is shipped with multi-layer protective packaging to prevent transit damage.

Order Tracking Available
A tracking ID will be shared once the product is dispatched.

Quality Checked Before Dispatch
Every machine is tested before shipping to ensure proper functioning.

Return & Refund Policy

7-Day Return Policy
Returns are accepted within 7 days only if the product is damaged, defective, or incorrect.

Full Refund or Replacement
After verification, customers may choose a full refund or product replacement.

Proof Required

Clear photos or videos of the damage/defect must be submitted for approval.

Non-Returnable Conditions
Items cannot be returned if they are used, tampered with, or physically damaged by the customer.

  • 100% Genuine Products
  • Fast & Safe Delivery
  • Expert Customer Assistance
View full details