{"product_id":"bmc-resmart-gii-bpap-system-y-30t","title":"BMC RESmart GII BPAP System Y-30T","description":"\u003cp\u003eAn intelligent technology, featured in the RESmart GII Y series, it delivers automatic solution for patients with OSA and\/or\u003cbr\u003erespiratory insufficiency. Aligned with same platform as RESmart GII BPAP System, Y series adapt pressure automatically to\u003cbr\u003epatient’s needs and provide a better synchronization.\u003c\/p\u003e\n\u003cp\u003eSpecifications:-\u003cbr\u003e\u003cstrong\u003eDevice Size\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDimensions:\u003c\/span\u003e 170 mm × 180 mm × 118 mm, or 290 mm × 180 mm × 134 mm (with the\u003cbr\u003ehumidifier)\u003cbr\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWeight:\u003c\/span\u003e 1.5 kg, or 2.5 kg (with the humidifier)\u003cbr\u003e\u003cstrong\u003eProduct Use, Transport and Storage\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"text-decoration: underline;\"\u003eOperation \u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eTemperature: 5°C to 35°C (41˚F to 95˚F)\u003cbr\u003eHumidity: 15% to 93% Non-condensing \u003cbr\u003eAtmospheric Pressure: 760 to 1060 hPa\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003eTransport and Storage\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e -25°C to 70°C (-13˚F to 158˚F)\u003cbr\u003e15% to 93% Non-condensing\u003cbr\u003e760 to 1060 hPa\u003cspan style=\"text-decoration: underline;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMode of Operation\u003c\/strong\u003e\u003cbr\u003eContinuous\u003cbr\u003e\u003cstrong\u003eWork Mode\u003c\/strong\u003e\u003cbr\u003eCPAP, S, AutoS, AutoCPAP, S\/T, T\u003cbr\u003e\u003cstrong\u003eSD Card\u003c\/strong\u003e\u003cbr\u003eSD card can record patient data and fault information.\u003cbr\u003e\u003cstrong\u003eAC Power Consumption\u003c\/strong\u003e\u003cbr\u003e100 – 240 V ～ 2 – 1 A, 50 \/ 60 Hz\u003cbr\u003e\u003cstrong\u003eMain Device offer to USB Communications Port\u003c\/strong\u003e\u003cbr\u003e5 V 2.0 A\u003cbr\u003e\u003cstrong\u003eMain Device offer to Humidifier\u003c\/strong\u003e\u003cbr\u003e24 V 1.5 A\u003cbr\u003e\u003cstrong\u003eType of Protection against Electric Shock\u003c\/strong\u003e\u003cbr\u003eClass II Equipment\u003cbr\u003e\u003cstrong\u003eDegree of Protection against Electric Shock\u003c\/strong\u003e\u003cbr\u003eType BF Applied Part\u003cbr\u003e\u003cstrong\u003eDegree of Protection against Ingress of Water\u003c\/strong\u003e\u003cbr\u003eIP22\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIPAP:   4.0 ～ 30.0 hPa (only applies to Y-30T, U-30T, U-30AT); in 0.5 hPa increments.\u003cbr\u003eEPAP:  4.0 ～ 25.0 hPa (only applies to\u003cbr\u003eY-25T, Y-30T, U-25T, U-30T, U-30AT); in 0.5 hPa increments.\u003cbr\u003eCPAP mode: 4.0 ～ 20.0 hPa\u003cbr\u003eUnder single fault conditions, ≤ 30 hPa for CPAP mode, ≤ 40 hPa for the rest modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Display Accuracy\u003c\/strong\u003e\u003cbr\u003e± (0.8 hPa＋4%)\u003cbr\u003e\u003cstrong\u003eStatic Pressure Stability\u003c\/strong\u003e\u003cbr\u003e± 0.5 hPa\u003cbr\u003e\u003cstrong\u003eRamp\u003c\/strong\u003e\u003cbr\u003eThe ramp time ranges from 0 to 60 minutes.\u003cbr\u003e\u003cstrong\u003eSound Pressure Level\u003c\/strong\u003e\u003cbr\u003e\u0026lt; 30 dB, when the device is working at the pressure of 10 hPa.\u003cbr\u003e\u003cstrong\u003eSound Power Level\u003c\/strong\u003e\u003cbr\u003e\u0026lt; 38 dB, when the device is working at the pressure of 10 hPa.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpO2\u003c\/strong\u003e\u003cbr\u003eRange: 0 ～ 100%\u003cbr\u003eThe margin of error for SpO2 between 70% and 100% is ± 3%. No strict accuracy\u003cbr\u003erequirements for SpO2 below 70%.\u003cbr\u003e\u003cstrong\u003ePulse Rate\u003c\/strong\u003e\u003cbr\u003eRange: 40 ～ 240 BPM\u003cbr\u003eMargin of Error: ± 1%\u003cbr\u003e\u003cstrong\u003eWavelengths\u003c\/strong\u003e\u003cbr\u003eRed: 663 nanometers\u003cbr\u003eInfrared: 890 nanometers\u003cbr\u003e\u003cstrong\u003eMaximal Optical Output Power\u003c\/strong\u003e\u003cbr\u003eLess than 1.5 mW maximum average.\u003cbr\u003e\u003cstrong\u003eTube\u003c\/strong\u003e\u003cbr\u003eLength: 6 ft. (1.83 m)\u003cbr\u003e\u003cstrong\u003eThe Form and the Dimensions of the Patient Connection Port\u003c\/strong\u003e\u003cbr\u003eThe 22 mm conical air outlet complies with ISO 5356-1.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eMaximum Flow\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 97.4774%; height: 364px;\" height=\"107\" width=\"455\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5909px;\"\u003e\n\u003ctd style=\"width: 42.3077%; height: 19.5909px;\"\u003eTest Pressure (hPa)\u003c\/td\u003e\n\u003ctd style=\"width: 8.46154%; height: 19.5909px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"width: 11.2207%; height: 19.5909px;\"\u003e 9\u003c\/td\u003e\n\u003ctd style=\"width: 13.9799%; height: 19.5909px;\"\u003e15\u003c\/td\u003e\n\u003ctd style=\"width: 16.3712%; height: 19.5909px;\"\u003e20\u003c\/td\u003e\n\u003ctd style=\"width: 6.43813%; height: 19.5909px;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7727px;\"\u003e\n\u003ctd style=\"width: 42.3077%; height: 58.7727px;\"\u003eMeasured Pressure at the\u003cbr\u003ePatient Connection Port\u003cbr\u003e(hPa)\u003c\/td\u003e\n\u003ctd style=\"width: 8.46154%; height: 58.7727px;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 11.2207%; height: 58.7727px;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"width: 13.9799%; height: 58.7727px;\"\u003e14\u003c\/td\u003e\n\u003ctd style=\"width: 16.3712%; height: 58.7727px;\"\u003e19\u003c\/td\u003e\n\u003ctd style=\"width: 6.43813%; height: 58.7727px;\"\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1818px;\"\u003e\n\u003ctd style=\"width: 42.3077%; height: 39.1818px;\"\u003eAverage Flow at the Patient\u003cbr\u003eConnection Port (L\/min)\u003c\/td\u003e\n\u003ctd style=\"width: 8.46154%; height: 39.1818px;\"\u003e93.2\u003c\/td\u003e\n\u003ctd style=\"width: 11.2207%; height: 39.1818px;\"\u003e97.6\u003c\/td\u003e\n\u003ctd style=\"width: 13.9799%; height: 39.1818px;\"\u003e978.1\u003c\/td\u003e\n\u003ctd style=\"width: 16.3712%; height: 39.1818px;\"\u003e98.5\u003c\/td\u003e\n\u003ctd style=\"width: 6.43813%; height: 39.1818px;\"\u003e99.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 296.455px;\"\u003e\n\u003ctd style=\"width: 42.3077%; height: 296.455px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 8.46154%; height: 296.455px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 11.2207%; height: 296.455px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 13.9799%; height: 296.455px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.3712%; height: 296.455px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 6.43813%; height: 296.455px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Medical Yantra","offers":[{"title":"Default Title","offer_id":45642956406934,"sku":"BMC GII Y-30T","price":27700.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/0029\/7622\/files\/y-25t-y-30t-2_3c70e74d-19e5-407b-a9e9-035535ad8895.jpg?v=1758527426","url":"https:\/\/99rj7y-01.myshopify.com\/products\/bmc-resmart-gii-bpap-system-y-30t","provider":"Medical Yantra","version":"1.0","type":"link"}